Private rented property standards guidance

Property standards checklist

Each section has a brief overview of the property standards guidance requirements. 

To ensure your property meets the standard please refer to the full guidance document.

1. Fire safety standards and means of escape 

Single person / family dwelling

ItemRequirementChecked
The correct fire detection based on the type and size of the property must be installed, you can consult LACORS Fire Safety Guidance (opens new window) and BS5839:6 2019. 
Smoke alarmsA smoke alarm installed on each storey of the house on which there is a room used wholly or partly as living accommodation, (including a bathroom, lavatory, hall, or landing). 
 

That smoke alarm is kept in proper working order and that it is tested on the first day of any new tenancy and on regular intervals thereafter.

 
Testing recordsMaintain a documented record of smoke alarm tests done on start of tenancy and inspection dates. 
Detector placementAlarms must be ceiling-mounted, 300mm from walls, and installed as per manufacturer's instructions. 
Escape routesPreferably not through risk rooms (kitchen living room), must be clear, well-lit, and well-constructed. 
Fire separationFloors, walls, and ceilings should be of sound, conventional construction.  
Basement / underfloor storageBasement or cellar must have fire-rated separation between it and the ground floor escape route. 
Fire fighting equipmentChecked / serviced where applicable, *fire blanket / extinguishers 
Inner roomsEscape route is through another room, this is termed an 'inner room' and poses a risk to its occupier if a fire starts unnoticed in the outer room (sometimes termed an 'access room'). This arrangement should be avoided wherever possible. Check guidance and additional fire detection
Fire escape windowsUnobstructed openable area that is at least 0.33m² and have a minimum 450mm height and 450mm width. The bottom of the openable area should not be more than 1,100mm above the floor. 
Other fire safety requirements
  • Polystyrene ceiling and wall tiles are not permitted.
  • Locks fitted to bedroom doors are to be openable from the inside without the use of a key.
  • Fire safety instructions for residents at commencement of the tenancy.
 
FurnitureFurniture provided by the landlord must comply with The Furniture and Furnishings (Fire) (Safety) Regulations 1988 (as amended) (opens new window) 

2. Gas safety and carbon monoxide 

ItemRequirementChecked
Annual gas safety checksAll gas appliances must be checked annually by a Gas Safe registered engineer. Retain certificates for two years. Licence properties retain full term of licence. 
Gas certificate to tenantsCopy given at tenancy start and on renewal of certificate. 
Carbon Monoxide (CO) Alarm    Install in any room with fixed combustion appliance (not gas cooker), tested regularly.  
 CO alarm is kept in proper working order and that it is tested on the first day of any new tenancy and on regular intervals thereafter. 
Gas meter accessibility    Each meter and supply cut-off must be accessible. 
External meter housing (gas / electric / water)  Good condition with a lockable door/hatch. 

3. Electrical safety

ItemRequirementChecked
Electrical Installation Condition Report (EICR)An EICR is required every five years. Must be done by a qualified electrician and copies given to tenant and council. 
Unsatisfactory EICRs    Where EICR is unsatisfactory, remedial works must be carried out within 28 days and supported by MEIWC, DEIC, or EIC. 
Electric meters/fuses     Must be accessible, not behind furniture/appliances. 
PAT testing (annual)    All provided electrical appliances over 12 months old must be tested annually with a PAT certificate submitted to council. 

4. Overcrowding and room sizes

ItemRequirementChecked
Occupancy limit        Based on Housing Act 1985 and room size, age and gender of occupants. 
Room usage        Only living rooms and bedrooms may be used for sleeping. the room must not contain any shared facilities (kitchen / bathroom)  or be the through route to such rooms or facilities. 
Minimum room sizes    Bedroom size must be over 6.5m² to be used for sleeping. 
 The usable space in a room with a sloping ceiling is calculated from the point at which the ceiling is 1.5m from the ground. 

5. Noise

ItemRequirementChecked
 Property must be suitably protected from external noise. 
Preventative measures to consider    Check Guidance for additional measures to consider. 

6. Pests

ItemRequirementChecked
PestsProperties must be free from pests of any type. 
Preventative measures to consider    Check Guidance for additional measures to consider. 

7. Legionella

ItemsRequirementChecked
 Identify and assess sources of risk to water systems within the property including; cold water tanks, hot water cylinders, pipework, taps and shower systems. 
 Manage any risks. 
 Prevent or control any risks. 
 Keep and maintain the correct records. 

8. Asbestos and manufactured mineral fibres (MMF)

ItemsRequirementChecked
Asbestos presenceIdentify location and condition of any asbestos.  
Asbestos Survey by specialist approved contractor    Needed if damaged or likely to be disturbed.Yes
No
Manufactured Mineral Fibres (MMF)Identify location and condition of any MMF.
Prevent exposure during maintenance.
 

9. Internal room standards

ItemRequirementChecked
CeilingsFree from all defects, structurally sound, no sagging or cracking.
Free from damp and mould.
 
WallsFree from all defects, structurally sound, no sagging or cracking.
Free from damp and mould., cleanable, no damp or mould.
 
FloorsStructurally sound and level, free of trip hazards.
Free from damp and mould properly covered for the intended use. 
 
Doors and framesFree from all defects open and close as intended, secure, good condition. 
Doors with glazingAny door with glazing must contain glazing that is either;
  • toughened safety glass
  • laminated glass
 
Windows

Free from all defects, Secure, open/close properly. 

Window restrictors where the sill height is less than 1100mm and the window opens wider than 100mm.

 
Blind safetyAll blinds with a cord provided by the owner, agent or landlord must be fitted with a suitable safety device to prevent accidents. 
Fireplace / surroundAll Fireplaces and surrounds must be fixed securely to the adjacent wall. 
Lighting points / switchingEach Room must have adequate lighting.
Must be free from defects. 
Appropriate lighting in bathrooms IP rated in accordance with its location.
 
Electrical socketsFree from defects.
Suitably located within the room.
Adequate number of electrical sockets within the room.
Sockets must be in a suitable location for the safe use of appliances.
Refer to guidance Table 2.
 
Radiators / heatersMust be fully operational, free from leaks, and securely fixed.
Appropriately sized for the room and have functional valves fully controllable by the tenant at all times.
 

10. Heating, insulation and ventilation

ItemRequirementChecked
EPC requirement    Minimum rating E, unless exempt is registered. 
Heating systems    Must heat rooms adequately and be controllable.
Each room must have fixed heating that can maintain 18 to 21°C at -1°C external temperature.
 
InsulationLoft insulation min 270mm, draught-proofing, double glazing.
Cavity wall insulation.
 
VentilationSufficient and appropriate means of ventilation across the whole property to deal with moisture generated by normal domestic activities without the need to open windows.  

11. Bathing and sanitary facilities

ItemRequirementChecked
Bathroom amenitiesBathroom amenities in good working order and well maintained.
WC, bath/shower, wash basin with hot/cold water.
 
Mechanical extractionRequired unless adequate natural ventilation and no issues with condensation / mould growth. 
Waste Plumbing pipe workMust be sealed, properly installed and undamaged. Drainage to a suitable outlet. 

12. Kitchen facility standards

ItemRequirementChecked
Sink and drainerIn good working order and well maintained.
Hot/cold water supply, sealed to worktop.
 
Work surfaces In good working order and well maintained.
Smooth, cleanable, sealed to wall.
 
StorageAdequate cupboards and shelves for food. 
SocketsSufficient number, correctly placed above the worktop.  
VentilationRequired unless adequate natural ventilation and no issues with condensation / mould growth. 

13. Stairs, landings, hallways

ItemRequirementChecked
StairsFree from defects, sound secure condition.
Even treads/risers, handrails fitted the full length of the stairs.
 
LightingSufficient to light the full staircase / hall  with 2-way switching on stairs. 
GuardingHeight should be between 900mm and 1000mm
Must prevent falls, gaps under 100mm.
 

14. Loft / attic

ItemRequirementChecked
Loft accessSafe, accessible, ideally with ladder. 
Lighting / loft access ladderRecommended for inspection and maintenance. 

15. External property standards

ItemRequirementChecked
Roof condition        Free from defects.
No loose tiles, weatherproof, properly flashed.
 
Chimney            Secure, undamaged, free from vegetation, properly flashed. 
Rainwater goods      Free from defects, securely fitted, Properly discharging, not leaking.  
Brickwork and pointing    Sound condition, no water ingress, DPC fitted in good condition.
Renders in sound condition. 
 

16. Gardens and yards

ItemRequirementChecked
CleanlinessFree from defects and waste, trip hazards, moss/algae. 
BoundaryFences, walls and gates in good repair. 
LightingSufficient for safe use. 

17. Waste provision

ItemRequirementChecked
Bins providedHousehold waste bin provided.
Recycling waste bin provided.
Clearly marked.
 
Access for collectionAccessible, clear path, no steep steps.